{"product_id":"125kva-perkins-diesel-generator-set-open-silent-type","title":"125kVA Perkins Diesel Generator Set – Open \u0026 Silent Type Options","description":"\u003cp data-start=\"407\" data-end=\"792\"\u003eThe 125kVA Perkins Diesel Generator Set is a high-capacity power generation solution designed for businesses and facilities that require dependable and uninterrupted electricity. Powered by the proven Perkins 1106A-70TG1 diesel engine and matched with a premium alternator, this generator delivers stable three-phase power with outstanding fuel efficiency, reliability, and durability.\u003c\/p\u003e\n\u003cp data-start=\"794\" data-end=\"1243\"\u003eDesigned for both standby and prime power applications, the 125kVA generator is ideal for manufacturing facilities, warehouses, construction projects, hotels, hospitals, office parks, farms, telecommunications infrastructure, and large commercial operations. It provides sufficient power to support machinery, refrigeration systems, pumps, air conditioning units, lighting systems, telecommunications equipment, and other essential electrical loads.\u003c\/p\u003e\n\u003cp data-start=\"1245\" data-end=\"1709\"\u003eThe generator is available in both silent canopy and open-frame versions to suit different installation requirements. The silent canopy model features a sound-attenuated enclosure that helps minimize operational noise, making it suitable for hospitals, hotels, schools, office complexes, and residential developments. The open-frame version offers convenient access for servicing and maintenance and is ideal for industrial facilities and plant room installations.\u003c\/p\u003e\n\u003cp data-start=\"1711\" data-end=\"1978\"\u003eBuilt with industrial-grade components and engineered for long-term reliability, the 125kVA Perkins generator provides exceptional performance, lower operating costs, and reduced downtime, ensuring that critical operations continue uninterrupted during power outages.\u003c\/p\u003e\n\u003ch2 data-section-id=\"1ma7m6t\" data-start=\"1980\" data-end=\"1995\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1997\" data-end=\"2440\"\u003e\n\u003cli data-section-id=\"1vdnwj1\" data-start=\"1997\" data-end=\"2026\"\u003eRated Power: 125kVA (100kW)\u003c\/li\u003e\n\u003cli data-section-id=\"15pqaqr\" data-start=\"2027\" data-end=\"2062\"\u003ePerkins 1106A-70TG1 diesel engine\u003c\/li\u003e\n\u003cli data-section-id=\"9ci22s\" data-start=\"2063\" data-end=\"2089\"\u003eThree-phase power output\u003c\/li\u003e\n\u003cli data-section-id=\"oirpja\" data-start=\"2090\" data-end=\"2140\"\u003eAvailable in silent canopy and open-frame models\u003c\/li\u003e\n\u003cli data-section-id=\"k4hbnv\" data-start=\"2141\" data-end=\"2192\"\u003eSuitable for standby and prime power applications\u003c\/li\u003e\n\u003cli data-section-id=\"fhsfsx\" data-start=\"2193\" data-end=\"2226\"\u003eFuel-efficient diesel operation\u003c\/li\u003e\n\u003cli data-section-id=\"i1wuvr\" data-start=\"2227\" data-end=\"2257\"\u003eHeavy-duty alternator system\u003c\/li\u003e\n\u003cli data-section-id=\"wvbwz\" data-start=\"2258\" data-end=\"2285\"\u003eStable voltage regulation\u003c\/li\u003e\n\u003cli data-section-id=\"5blasq\" data-start=\"2286\" data-end=\"2317\"\u003eIndustrial-grade construction\u003c\/li\u003e\n\u003cli data-section-id=\"pn4kg1\" data-start=\"2318\" data-end=\"2350\"\u003eReliable long-term performance\u003c\/li\u003e\n\u003cli data-section-id=\"jwvadb\" data-start=\"2351\" data-end=\"2376\"\u003eEasy maintenance access\u003c\/li\u003e\n\u003cli data-section-id=\"14a1p4h\" data-start=\"2377\" data-end=\"2440\"\u003eDesigned for demanding commercial and industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-section-id=\"1a3ueyz\" data-start=\"2442\" data-end=\"2459\"\u003eSpecifications\u003c\/h2\u003e\n\u003ch3 data-section-id=\"1dwylfb\" data-start=\"2461\" data-end=\"2476\"\u003eSilent Type\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2478\" data-end=\"2749\"\u003e\n\u003cthead data-start=\"2478\" data-end=\"2505\"\u003e\n\u003ctr data-start=\"2478\" data-end=\"2505\"\u003e\n\u003cth class=\"last:pe-10\" data-start=\"2478\" data-end=\"2494\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-start=\"2494\" data-end=\"2505\" data-col-size=\"sm\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2533\" data-end=\"2749\"\u003e\n\u003ctr data-start=\"2533\" data-end=\"2565\"\u003e\n\u003ctd data-start=\"2533\" data-end=\"2547\" data-col-size=\"sm\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-start=\"2547\" data-end=\"2565\" data-col-size=\"sm\"\u003e100kW \/ 125kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2566\" data-end=\"2598\"\u003e\n\u003ctd data-start=\"2566\" data-end=\"2575\" data-col-size=\"sm\"\u003eEngine\u003c\/td\u003e\n\u003ctd data-start=\"2575\" data-end=\"2598\" data-col-size=\"sm\"\u003ePerkins 1106A-70TG1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2599\" data-end=\"2627\"\u003e\n\u003ctd data-start=\"2599\" data-end=\"2612\" data-col-size=\"sm\"\u003eAlternator\u003c\/td\u003e\n\u003ctd data-start=\"2612\" data-end=\"2627\" data-col-size=\"sm\"\u003eKS KAL274C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2628\" data-end=\"2648\"\u003e\n\u003ctd data-start=\"2628\" data-end=\"2640\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"2640\" data-end=\"2648\" data-col-size=\"sm\"\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2649\" data-end=\"2671\"\u003e\n\u003ctd data-start=\"2649\" data-end=\"2659\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2659\" data-end=\"2671\"\u003e400\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2672\" data-end=\"2691\"\u003e\n\u003ctd data-start=\"2672\" data-end=\"2680\" data-col-size=\"sm\"\u003ePhase\u003c\/td\u003e\n\u003ctd data-start=\"2680\" data-end=\"2691\" data-col-size=\"sm\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2692\" data-end=\"2729\"\u003e\n\u003ctd data-start=\"2692\" data-end=\"2705\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2705\" data-end=\"2729\"\u003e3400 × 1100 × 1450mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2730\" data-end=\"2749\"\u003e\n\u003ctd data-start=\"2730\" data-end=\"2739\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2739\" data-end=\"2749\"\u003e1846kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"fg1n8q\" data-start=\"2751\" data-end=\"2764\"\u003eOpen Type\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\" data-start=\"2766\" data-end=\"3036\"\u003e\n\u003cthead data-start=\"2766\" data-end=\"2793\"\u003e\n\u003ctr data-start=\"2766\" data-end=\"2793\"\u003e\n\u003cth class=\"last:pe-10\" data-start=\"2766\" data-end=\"2782\" data-col-size=\"sm\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\" data-start=\"2782\" data-end=\"2793\" data-col-size=\"sm\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2821\" data-end=\"3036\"\u003e\n\u003ctr data-start=\"2821\" data-end=\"2853\"\u003e\n\u003ctd data-start=\"2821\" data-end=\"2835\" data-col-size=\"sm\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2835\" data-end=\"2853\"\u003e100kW \/ 125kVA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2854\" data-end=\"2886\"\u003e\n\u003ctd data-start=\"2854\" data-end=\"2863\" data-col-size=\"sm\"\u003eEngine\u003c\/td\u003e\n\u003ctd data-start=\"2863\" data-end=\"2886\" data-col-size=\"sm\"\u003ePerkins 1106A-70TG1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2887\" data-end=\"2915\"\u003e\n\u003ctd data-start=\"2887\" data-end=\"2900\" data-col-size=\"sm\"\u003eAlternator\u003c\/td\u003e\n\u003ctd data-col-size=\"sm\" data-start=\"2900\" data-end=\"2915\"\u003eKS KAL274C2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2916\" data-end=\"2936\"\u003e\n\u003ctd data-start=\"2916\" data-end=\"2928\" data-col-size=\"sm\"\u003eFrequency\u003c\/td\u003e\n\u003ctd data-start=\"2928\" data-end=\"2936\" data-col-size=\"sm\"\u003e50Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2937\" data-end=\"2959\"\u003e\n\u003ctd data-start=\"2937\" data-end=\"2947\" data-col-size=\"sm\"\u003eVoltage\u003c\/td\u003e\n\u003ctd data-start=\"2947\" data-end=\"2959\" data-col-size=\"sm\"\u003e400\/230V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2960\" data-end=\"2979\"\u003e\n\u003ctd data-start=\"2960\" data-end=\"2968\" data-col-size=\"sm\"\u003ePhase\u003c\/td\u003e\n\u003ctd data-start=\"2968\" data-end=\"2979\" data-col-size=\"sm\"\u003e3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2980\" data-end=\"3016\"\u003e\n\u003ctd data-start=\"2980\" data-end=\"2993\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-start=\"2993\" data-end=\"3016\" data-col-size=\"sm\"\u003e2400 × 950 × 1200mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3017\" data-end=\"3036\"\u003e\n\u003ctd data-start=\"3017\" data-end=\"3026\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"3026\" data-end=\"3036\" data-col-size=\"sm\"\u003e1363kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 data-section-id=\"mu966k\" data-start=\"3038\" data-end=\"3053\"\u003eApplications\u003c\/h2\u003e\n\u003cul data-start=\"3055\" data-end=\"3345\"\u003e\n\u003cli data-section-id=\"pq5ogs\" data-start=\"3055\" data-end=\"3077\"\u003eManufacturing plants\u003c\/li\u003e\n\u003cli data-section-id=\"1ykt2la\" data-start=\"3078\" data-end=\"3112\"\u003eWarehouses and logistics centres\u003c\/li\u003e\n\u003cli data-section-id=\"3ovaz8\" data-start=\"3113\" data-end=\"3133\"\u003eHotels and resorts\u003c\/li\u003e\n\u003cli data-section-id=\"ftm1pq\" data-start=\"3134\" data-end=\"3171\"\u003eHospitals and healthcare facilities\u003c\/li\u003e\n\u003cli data-section-id=\"k8cei5\" data-start=\"3172\" data-end=\"3192\"\u003eConstruction sites\u003c\/li\u003e\n\u003cli data-section-id=\"d2lu6v\" data-start=\"3193\" data-end=\"3218\"\u003eAgricultural operations\u003c\/li\u003e\n\u003cli data-section-id=\"1ls089w\" data-start=\"3219\" data-end=\"3254\"\u003eTelecommunications infrastructure\u003c\/li\u003e\n\u003cli data-section-id=\"1dbuo6a\" data-start=\"3255\" data-end=\"3284\"\u003eCommercial office complexes\u003c\/li\u003e\n\u003cli data-section-id=\"w99ukr\" data-start=\"3285\" data-end=\"3312\"\u003eMining support operations\u003c\/li\u003e\n\u003cli data-section-id=\"13oe9mu\" data-start=\"3313\" data-end=\"3345\"\u003eEmergency backup power systems\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Container World Pty Ltd","offers":[{"title":"New","offer_id":71511403757821,"sku":"CW-GTM-202606067002","price":702899.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0831\/7396\/6077\/files\/ChatGPT-Image-Jun-6-2026-01_02_05-PM-1_aa733b17-d977-4006-a1e8-eca0c2822c3d.png?v=1791509749","url":"https:\/\/containersworld.co.za\/products\/125kva-perkins-diesel-generator-set-open-silent-type","provider":"Container World Pty Ltd","version":"1.0","type":"link"}